Homes in Cornwall (TR16) at a glance
This page summarises 5,574 energy performance certificates (EPCs) for homes in Cornwall (TR16), using the most recent certificate for each home. 67% are rated D or lower, and 40% are rated E, F or G.
The median floor area is about 83 m².
Half of these certificates were issued in 2019 or later, so most describe homes as they are now or were within the last few years.
What kinds of homes are here
Detached and semi-detached homes account for 70% of certificates. These usually have room for an outdoor heat pump unit and a cylinder, but more exposed wall and roof area means insulation quality has a large effect on how well a heat pump performs.
Bungalows are 30% of the sample. They tend to have a large roof area relative to floor area, so loft insulation is usually worth checking first.
Who owns the homes here
Of the certificates that record tenure, 70% are owner-occupied homes, so most upgrade decisions here sit with the people who live in them. 19% are privately rented and 11% socially rented.
Walls and insulation
32% of the sampled homes have solid walls. These lose more heat than insulated cavity walls and cannot be filled like a cavity, so options are internal or external wall insulation, which cost more and take more planning. A heat pump can still work in a solid-wall home, but a proper heat-loss survey matters, and it is worth asking installers how they sized the system.
Much of that is stone rather than brick: 30% of homes have sandstone, limestone, granite or similar walls. Stone walls usually need breathable (vapour-open) insulation materials, so ask installers how they would handle moisture.
How homes are heated
Only 22% of homes here are recorded as using mains gas. The largest non-gas group is oil at 36%. Homes without mains gas are often the first to be advised to consider a heat pump, because the comparison is with oil, LPG or electric heating rather than cheap mains gas. Running costs still depend on insulation, tariff and how the system is designed.
13% of certificates already record a heat pump as the main heating, so there is some local precedent for neighbours to ask about.
When homes were built
Building age is spread across eras: 30% before 1930, 27% from 1930 to 1975, 17% from 1976 to 2002 and 26% from 2003. Advice should follow the individual home's construction rather than the area average.
Lofts and windows
13% of homes with a roof of their own have no loft or roof insulation recorded, or less than 100 mm. For those homes a top-up to about 270 mm is the usual EPC recommendation.
Almost all homes here are double or triple glazed: 10% have any single glazing recorded.
Energy ratings
40% of certificates are rated E, F or G. Homes at the bottom of the scale usually have the most to gain from basic measures such as loft and wall insulation and draught-proofing, and the EPC recommendation list is a good place to start.
Improvements suggested for homes in Cornwall (TR16)
Across the 5,574 certificates here, the improvements suggested most often are solar panels for electricity (85%), solar water heating (83%) and floor insulation (58%).
A heat pump is suggested on fewer than 1% of certificates here, which says more about the assessment software than about the homes.
Solar water heating is suggested more often here than across Cornwall: on 83% of certificates, against 69%.
Ask an installer about solar panels insulation
Heat pump grants across Cornwall
Boiler Upgrade Scheme figures are published for local authorities, not postcode districts. Across Cornwall, 3,448 heat pump installations have had a grant paid (May 2022 to September 2026).
Installers in and around Cornwall (TR16)
Companies House-registered installers listed for Cornwall: 25 installers have their registered office within 7 miles and 77 more say on their website that they work across Cornwall. 50 of the 102 mention heat pumps.
The typical firm has been trading for 9 years (the median, from Companies House incorporation dates).
The first listed are CCS Heating & Renewables Ltd, Alphaone Electrics Ltd and Jose & Blackler Limited.
CCS Heating & Renewables Ltd
Says it fits air source heat pump, ground source heat pump, air to air heat pump, solar PV, battery storage, EV charging, underfloor heating, boilers
Says it holds MCS, TrustMark, HIES, Gas Safe
Alphaone Electrics Ltd
Says it fits air source heat pump, solar PV, battery storage, EV charging
Says it holds MCS
Jose & Blackler Limited
Says it fits air source heat pump, ground source heat pump, solar thermal, underfloor heating, boilers
Says it holds MCS
C S Electrical South West Limited
Says it fits ground source heat pump, solar PV, battery storage, EV charging
Says it holds MCS, NICEIC
Heat Pump Pro Ltd
Says it fits air source heat pump, ground source heat pump, solar PV, solar thermal, underfloor heating, boilers
Armor Electrical Limited
Says it fits air source heat pump, solar PV, battery storage
Shiney Electrical Ltd
Says it fits solar PV, battery storage, EV charging
Says it holds MCS, TrustMark, RECC, NAPIT
Ignite Mechanical Electrical Solutions Ltd
Says it fits solar PV
Says it holds MCS, TrustMark, RECC
Trezona Electrical Contractors Limited
North Coast Plumbing & Heating Ltd
Heath & Arnold Limited
Natural Spark Ltd
JP Electrical South West Ltd
D & R Electrical Installations Limited
Boxt Electrical Ltd
Says it fits solar PV, battery storage, EV charging
Says it holds NAPIT
Duchy Electrical Ltd
Ibex Heating Ltd
Davanna Heating Limited
Cornish Solar Ltd
Energlow Electrical and Renewables Ltd
Says it fits solar PV, battery storage, EV charging
Earth Energies Ltd
Says it fits solar PV, battery storage, EV charging
Wired By Jessops Limited
Blue Flame (Cornwall) Limited
ATG Plumbing & Heating Ltd
These are the first 24 of 102: firms that name this area first, then those with a registered office nearby, then those that cover the wider area; heat pump firms and the nearest first within each.
Listed from each firm's own website and from Companies House records (contains public sector information licensed under the Open Government Licence v3.0). Being listed is not a recommendation, and what firms say about themselves has not been checked: ask for an installer's MCS certificate number and consumer code membership before you sign anything.
How Cornwall (TR16) compares with Cornwall
Homes not on mains gas are more common here than across Cornwall: 78% of certificates, against 51%.
Homes rated E, F or G are more common here than across Cornwall: 40% of certificates, against 28%.
Flats are less common here than across Cornwall: 6% of certificates, against 17%.
Advice written for Cornwall as a whole may not fit Cornwall on these points.
Cornwall (TR16) and its neighbours
Redruth (TR15) is about 1 mile away. Homes not on mains gas are less common there: 25% of certificates, against 78% in Cornwall.
Camborne (TR14) is about 4 miles away. Homes not on mains gas are less common there: 31% of certificates, against 78% in Cornwall.
Cornwall (TR3) is about 5 miles away. Homes not on mains gas are less common there: 52% of certificates, against 78% in Cornwall (TR16).
Grants and support (England)
The Boiler Upgrade Scheme rules (who qualifies, what it covers and how the installer applies) are summarised on the Cornwall page, with a link to the official GOV.UK guidance.