Homes in Hyndburn at a glance
This page summarises 27,997 energy performance certificates (EPCs) for homes in Hyndburn, using the most recent certificate for each home. 63% are rated D or lower.
The median floor area is about 83 m².
Half of these certificates were issued in 2019 or later, so most describe homes as they are now or were within the last few years.
What kinds of homes are here
Terraced homes make up 64% of certificates. Mid-terraces lose less heat through shared walls, but outdoor space can be tight, so where an outdoor unit can go and how it affects neighbours is often the deciding factor.
Who owns the homes here
Tenure is mixed: of the certificates that record it, 59% are owner-occupied, 26% privately rented and 15% socially rented. Who can approve an upgrade differs between those groups, so it is worth knowing which applies before asking for quotes.
Privately rented homes in England and Wales must currently reach at least an E rating to be let, with some exemptions, and are upgraded by their landlords, so landlords are the people to talk to about those homes.
Walls and insulation
43% of the sampled homes have solid walls. These lose more heat than insulated cavity walls and cannot be filled like a cavity, so options are internal or external wall insulation, which cost more and take more planning. A heat pump can still work in a solid-wall home, but a proper heat-loss survey matters, and it is worth asking installers how they sized the system.
Much of that is stone rather than brick: 41% of homes have sandstone, limestone, granite or similar walls. Stone walls usually need breathable (vapour-open) insulation materials, so ask installers how they would handle moisture.
How homes are heated
95% of homes use mains gas, so for most households a heat pump would be replacing a gas boiler. Whether that saves money depends heavily on the electricity and gas price gap, the home's insulation and how efficiently the system runs, so compare itemised quotes rather than headline claims.
When homes were built
49% of homes were built before 1930. Older homes are more likely to have solid walls, suspended timber floors and period features, and some may be in conservation areas or listed, which can affect what changes are permitted. It is worth checking this before getting quotes.
Lofts and windows
28% of homes with a roof of their own have no loft or roof insulation recorded, or less than 100 mm. Loft insulation is usually one of the simpler upgrades, and EPC recommendations work towards about 270 mm. Rooms in the roof and flat roofs are harder and need a closer look.
Almost all homes here are double or triple glazed: 7% have any single glazing recorded.
Energy ratings
Most homes sit in bands C and D, with 19% rated E to G. For those homes the EPC recommendations are a useful check on which upgrades are still outstanding.
Improvements suggested for homes in Hyndburn
Across the 27,997 certificates here, the improvements suggested most often are solar panels for electricity (85%), solar water heating (70%) and floor insulation (53%).
A heat pump is suggested on fewer than 1% of certificates here, which says more about the assessment software than about the homes.
Solid wall insulation (internal or external) is suggested more often here than across North West: on 41% of certificates, against 19%.
Solar panels for electricity is suggested more often here than across North West: on 85% of certificates, against 73%.
Ask an installer about solar panels insulation
Heat pump grants in Hyndburn
44 heat pump installations in Hyndburn have had a Boiler Upgrade Scheme grant paid (May 2022 to September 2026).
Uptake has been fairly steady, from 15 grants in 2024/25 to 13 in 2025/26.
These count grant-funded installations only; heat pumps installed without a Boiler Upgrade Scheme grant are not included. Source: DESNZ Boiler Upgrade Scheme statistics.
Installers in and around Hyndburn
Companies House-registered installers listed for Hyndburn: 3 installers have their registered office in Hyndburn, 1 more says on its own website that it works there and 55 more only name the county it is in on their website. 30 of the 59 mention heat pumps.
The typical firm has been trading for 6 years (the median, from Companies House incorporation dates).
The first listed are LOW Carbon Installations Limited, Three Phase Contractors Limited and MHR Plumbing & Heating Ltd.
LOW Carbon Installations Limited
Says it fits air source heat pump, ground source heat pump, solar PV, solar thermal, battery storage, underfloor heating, boilers
Three Phase Contractors Limited
MHR Plumbing & Heating Ltd
ASC Electrical Services Limited
Says it fits solar PV, battery storage, EV charging
Says it holds MCS, RECC, NAPIT, CHAS
Says it fits ground source heat pump, underfloor heating, boilers
Says it holds MCS, Gas Safe, Which? Trusted Trader
Their website · More about High Efficiency Heating (UK) Limited
Says it fits air source heat pump, ground source heat pump, solar PV, solar thermal, battery storage, EV charging, underfloor heating
Says it holds MCS, TrustMark, RECC, Constructionline, Checkatrade
D Barlow & Sons Limited
Says it fits air source heat pump, ground source heat pump, biomass, boilers
Says it holds MCS, RECC, Gas Safe, OFTEC
Says it fits air source heat pump, ground source heat pump, solar PV, battery storage, underfloor heating, boilers
Says it holds MCS, Gas Safe, OFTEC
Their website · More about A Mellor Plumbing & Heating Services Limited
Says it fits air source heat pump, solar PV, battery storage, EV charging, boilers, cavity wall insulation, loft insulation, solid wall insulation
Says it holds MCS, TrustMark, Gas Safe
Ashburn Stoves Limited
Says it fits ground source heat pump, solar PV, solar thermal, biomass, boilers
Says it holds MCS
Says it fits air source heat pump, ground source heat pump, air to air heat pump, battery storage, underfloor heating, boilers
Says it holds MCS, TrustMark, HIES
Logic Plumbing Heating and Electrical (Maintenance) Limited
Says it fits air source heat pump, ground source heat pump, solar PV, solar thermal, battery storage, EV charging, boilers
Says it holds MCS, NICEIC, Gas Safe, HETAS
Plumbtec (NW) Ltd
Says it fits air source heat pump, ground source heat pump, boilers
Says it holds MCS, TrustMark, NAPIT
Says it fits air source heat pump, battery storage, boilers
Says it holds MCS, TrustMark, RECC, NAPIT, Gas Safe, Which? Trusted Trader, Checkatrade
Says it fits air source heat pump, ground source heat pump, solar PV, battery storage, boilers, cavity wall insulation, loft insulation, windows and doors
Says it holds MCS, TrustMark, RECC, HIES, PAS 2030, PAS 2035
Smarter Energy UK Ltd
Says it fits air source heat pump, air to air heat pump, solar PV, battery storage, EV charging, underfloor heating, boilers
Says it holds MCS, RECC
Says it fits air source heat pump, solar PV, battery storage, EV charging
Says it holds MCS, TrustMark, NICEIC, NAPIT
Says it fits air source heat pump, ground source heat pump, solar PV, battery storage, EV charging, underfloor heating, boilers, cavity wall insulation, loft insulation
Says it holds MCS, TrustMark, HIES, NAPIT
West Coast Electrical Contractors Ltd
Says it fits air source heat pump, solar PV, battery storage, EV charging, boilers
Says it holds MCS, TrustMark, RECC, NICEIC
Says it fits air source heat pump, air to air heat pump, solar PV, battery storage, EV charging, boilers, cavity wall insulation
Says it holds MCS, TrustMark, RECC, NAPIT
Plumbwise Limited
Says it fits air source heat pump, underfloor heating, boilers
Says it holds MCS
Green Improve Ltd
Says it fits air source heat pump, solar PV, battery storage, boilers, cavity wall insulation, loft insulation
Says it holds MCS, TrustMark, NAPIT, Gas Safe, CHAS, PAS 2030
Says it fits air source heat pump, solar PV, battery storage, boilers
Says it holds MCS, Gas Safe
Says it fits air source heat pump, ground source heat pump, air to air heat pump, solar PV, battery storage, EV charging, biomass, underfloor heating, boilers, cavity wall insulation
Says it holds MCS, TrustMark, RECC, HIES, NICEIC, NAPIT, ISO 9001, ISO 14001, PAS 2030
These are the first 24 of 59: firms that name this area first, then those with a registered office nearby, then those that cover the wider area; heat pump firms and the nearest first within each.
Listed from each firm's own website and from Companies House records (contains public sector information licensed under the Open Government Licence v3.0). Being listed is not a recommendation, and what firms say about themselves has not been checked: ask for an installer's MCS certificate number and consumer code membership before you sign anything.
How Hyndburn compares with North West
Homes built before 1930 are more common here than across North West: 49% of certificates, against 24%.
Homes with solid walls are more common here than across North West: 43% of certificates, against 19%.
Detached or semi-detached homes are less common here than across North West: 34% of certificates, against 52%.
Advice written for North West as a whole may not fit Hyndburn on these points.
Where Hyndburn varies
2 smaller areas within Hyndburn have enough certificates for their own page.
Overton (BB6) has the highest share of detached or semi-detached homes: 46%, against 34% across Hyndburn.
How Hyndburn ranks within North West
Of the 35 North West local authorities with a page on this site, Hyndburn has the 2nd-highest share of homes built before 1930 (49%).
Grants and support (England)
Boiler Upgrade Scheme: owners of homes in England and Wales, including landlords, can get £7,500 off an air source or ground source heat pump (£2,500 for an air-to-air heat pump) when it replaces fossil fuel heating such as gas, oil, LPG or electric heaters. The installer applies for the grant and it is taken off the price on the quote. Most new builds, social housing and hybrid systems are not eligible, and there is one grant per property.