Homes in Darlington at a glance
This page summarises 40,162 energy performance certificates (EPCs) for homes in Darlington, using the most recent certificate for each home. 52% are rated D or lower.
The median floor area is about 83 m².
Half of these certificates were issued in 2019 or later, so most describe homes as they are now or were within the last few years.
What kinds of homes are here
Terraced homes make up 42% of certificates. Mid-terraces lose less heat through shared walls, but outdoor space can be tight, so where an outdoor unit can go and how it affects neighbours is often the deciding factor.
Who owns the homes here
Tenure is mixed: of the certificates that record it, 64% are owner-occupied, 18% privately rented and 18% socially rented. Who can approve an upgrade differs between those groups, so it is worth knowing which applies before asking for quotes.
Walls and insulation
32% of the sampled homes have solid walls. These lose more heat than insulated cavity walls and cannot be filled like a cavity, so options are internal or external wall insulation, which cost more and take more planning. A heat pump can still work in a solid-wall home, but a proper heat-loss survey matters, and it is worth asking installers how they sized the system.
How homes are heated
91% of homes use mains gas, so for most households a heat pump would be replacing a gas boiler. Whether that saves money depends heavily on the electricity and gas price gap, the home's insulation and how efficiently the system runs, so compare itemised quotes rather than headline claims.
Among the homes that are not on gas, electric heating is the most common, at 6% of all homes here. Homes on direct electric or storage heating usually see the biggest change in running costs from a heat pump, because the comparison is with full-price electricity.
When homes were built
Building age is spread across eras: 28% before 1930, 32% from 1930 to 1975, 18% from 1976 to 2002 and 22% from 2003. Advice should follow the individual home's construction rather than the area average.
Lofts and windows
20% of homes with a roof of their own have no loft or roof insulation recorded, or less than 100 mm. For those homes a top-up to about 270 mm is the usual EPC recommendation.
11% of homes still have some single-glazed windows. In older or listed buildings, secondary glazing is often the permitted option.
Energy ratings
Most homes sit in bands C and D, with 15% rated E to G. For those homes the EPC recommendations are a useful check on which upgrades are still outstanding.
Improvements suggested for homes in Darlington
Across the 40,162 certificates here, the improvements suggested most often are solar panels for electricity (77%), solar water heating (66%) and floor insulation (54%).
A heat pump is suggested on fewer than 1% of certificates here, which says more about the assessment software than about the homes.
Solid wall insulation (internal or external) is suggested more often here than across North East: on 32% of certificates, against 16%.
Ask an installer about solar panels insulation
Heat pump grants in Darlington
146 heat pump installations in Darlington have had a Boiler Upgrade Scheme grant paid (May 2022 to September 2026).
Uptake has grown: 7 grants were paid in 2022/23 and 41 in 2025/26.
These count grant-funded installations only; heat pumps installed without a Boiler Upgrade Scheme grant are not included. Source: DESNZ Boiler Upgrade Scheme statistics.
Installers in and around Darlington
Companies House-registered installers listed for Darlington: 7 installers have their registered office in Darlington, 12 more say on their own website that they work there and 24 more only name the county it is in on their website. 13 of the 43 mention heat pumps.
The typical firm has been trading for 9 years (the median, from Companies House incorporation dates).
The first listed are Closecooper Renewables Ltd, Harvey Electrical Services (Northern) Limited and DMH Electrical and Renewable Ltd.
Closecooper Renewables Ltd
Says it fits air source heat pump, ground source heat pump, water source heat pump, hybrid heat pump, solar PV, battery storage, EV charging, underfloor heating, boilers
Says it holds RECC
Harvey Electrical Services (Northern) Limited
Says it fits solar PV, EV charging
Says it holds MCS, NAPIT
DMH Electrical and Renewable Ltd
Says it fits solar PV, battery storage, EV charging
Says it holds MCS, NICEIC
Darlington Solar Ltd
Says it fits solar PV, EV charging
Says it holds MCS
Eternal Energy Limited
Thistle Solutions Limited
Says it fits solar PV, boilers
Facility Six Ltd
Says it fits air source heat pump, ground source heat pump, solar PV, solar thermal, battery storage, EV charging, underfloor heating
Says it holds MCS, TrustMark, RECC, Constructionline, Checkatrade
Plumbcraft (Yorks) Ltd
Says it fits air source heat pump, solar thermal, underfloor heating, boilers
Says it holds Gas Safe, Checkatrade
Innovheat Ltd
Says it fits air source heat pump, solar PV, battery storage, EV charging, underfloor heating, boilers
Heat4energy Ltd
Says it fits air source heat pump, solar PV, boilers, cavity wall insulation, loft insulation
Sustainable Energy Engineering Limited
Says it fits solar PV, solar thermal, battery storage, EV charging
Says it holds MCS, TrustMark, RECC, Which? Trusted Trader
DDR Electrical Limited
Says it fits solar PV, battery storage, EV charging
Says it holds MCS, HIES, NICEIC
Advanced Renewable Power Ltd
Says it fits solar PV, battery storage
Says it holds MCS, ISO 9001
L&r Renewables Ltd
Says it fits solar PV, battery storage
Says it holds MCS, TrustMark, NAPIT, Checkatrade
Solarsave Ltd
Says it fits solar PV, battery storage, EV charging
Says it holds MCS, RECC, NAPIT
Alps Electrical Ltd
Says it fits solar PV, battery storage, EV charging
Says it holds MCS, TrustMark, RECC, NAPIT, Checkatrade
UCS Renewables Limited
Says it fits solar PV, EV charging
Gardiner Electrical & Properties Ltd
Says it fits solar PV, battery storage, EV charging
Says it holds NICEIC, CHAS
Says it fits air source heat pump, ground source heat pump, solar PV, solar thermal, battery storage, EV charging, biomass, underfloor heating, boilers
Says it holds MCS, TrustMark, RECC, NAPIT, Gas Safe, OFTEC, CHAS
Their website · More about Marshall Clean Heat and Power Ltd
Says it fits air source heat pump, ground source heat pump, air to air heat pump, battery storage, underfloor heating, boilers
Says it holds MCS, TrustMark, HIES
Says it fits air source heat pump, underfloor heating, boilers
Says it holds MCS, TrustMark, HIES, NAPIT, Gas Safe
Says it fits air source heat pump, battery storage, biomass, boilers, EV charging, ground source heat pump, loft insulation, solar PV
Says it holds HIES, MCS, PAS 2030
Arnies Plumbing Services Ltd
Says it fits air source heat pump, boilers
Says it holds MCS, TrustMark, RECC, NAPIT, Gas Safe, Checkatrade
These are the first 24 of 43: firms that name this area first, then those with a registered office nearby, then those that cover the wider area; heat pump firms and the nearest first within each.
Listed from each firm's own website and from Companies House records (contains public sector information licensed under the Open Government Licence v3.0). Being listed is not a recommendation, and what firms say about themselves has not been checked: ask for an installer's MCS certificate number and consumer code membership before you sign anything.
How Darlington compares with North East
Homes with solid walls are more common here than across North East: 32% of certificates, against 15%.
Advice written for North East as a whole may not fit Darlington on this point.
Where Darlington varies
3 smaller areas within Darlington have enough certificates for their own page.
Darlington (DL3) has the highest share of homes with solid walls: 44%, against 32% across Darlington.
Darlington (DL2) has the highest share of homes not on mains gas: 27%, against 9% across Darlington.
Darlington (DL3) has the highest share of homes built before 1930: 40%, against 28% across Darlington.
Darlington (DL2) has the highest share of detached or semi-detached homes: 74%, against 56% across Darlington.
How Darlington ranks within North East
Of the 12 North East local authorities with a page on this site, Darlington has the highest share of homes with solid walls (32%), the highest share of homes built before 1930 (28%) and the lowest share of socially rented homes (18%).
Grants and support (England)
Boiler Upgrade Scheme: owners of homes in England and Wales, including landlords, can get £7,500 off an air source or ground source heat pump (£2,500 for an air-to-air heat pump) when it replaces fossil fuel heating such as gas, oil, LPG or electric heaters. The installer applies for the grant and it is taken off the price on the quote. Most new builds, social housing and hybrid systems are not eligible, and there is one grant per property.