Homes in Hoxton East & Shoreditch (EC2A) at a glance
This page summarises 1,916 energy performance certificates (EPCs) for homes in Hoxton East & Shoreditch (EC2A), using the most recent certificate for each home. 16% are rated D or lower.
The median floor area is about 68 m².
Half of these certificates were issued in 2021 or later, so most describe homes as they are now or were within the last few years.
What kinds of homes are here
Flats make up 99% of the certificates here. For flats, the practical questions come before the technology: who owns the building, whether the freeholder or management company must approve external equipment, and whether there is space for a hot water cylinder indoors. Shared or communal systems are often a better fit than one-off installs in individual flats.
Who owns the homes here
66% of the certificates that record tenure are for privately rented homes, which is a high share. Privately rented homes in England and Wales must currently reach at least an E rating to be let, with some exemptions, and are upgraded by their landlords, so landlords are the people to talk to about those homes.
Owner-occupiers are 28% and social tenants 6%.
Walls and insulation
32% of the sampled homes have solid walls. These lose more heat than insulated cavity walls and cannot be filled like a cavity, so options are internal or external wall insulation, which cost more and take more planning. A heat pump can still work in a solid-wall home, but a proper heat-loss survey matters, and it is worth asking installers how they sized the system.
How homes are heated
Mains gas serves 75% of the sampled homes, so the area splits between households replacing a gas boiler and those already paying for another fuel, most often electric heating (9%). The sensible starting point differs between those two groups.
48% of homes are on a community or district heating scheme. Those households usually cannot choose their own heating system, so the relevant questions are about the scheme operator rather than an individual heat pump.
3% of certificates already record a heat pump as the main heating, so there is some local precedent for neighbours to ask about.
When homes were built
61% of homes date from 2003 or later. Newer homes are built to higher insulation standards and often have lower heat loss, which generally makes them easier candidates for a heat pump, though some have small cylinders or no space allocated for one.
Lofts and windows
29% of homes with a roof of their own have no loft or roof insulation recorded, or less than 100 mm. Loft insulation is usually one of the simpler upgrades, and EPC recommendations work towards about 270 mm. Rooms in the roof and flat roofs are harder and need a closer look.
16% of homes still have some single-glazed windows. In older or listed buildings, secondary glazing is often the permitted option.
Energy ratings
Most homes sit in bands C and D, with 4% rated E to G. For those homes the EPC recommendations are a useful check on which upgrades are still outstanding.
Improvements suggested for homes in Hoxton East & Shoreditch (EC2A)
Across the 1,916 certificates here, the improvements suggested most often are solid wall insulation (internal or external) (28%), double or secondary glazing (14%) and modern electric storage heaters (7%).
None of the certificates here suggests a heat pump, which says more about the assessment software than about the homes.
Solid wall insulation (internal or external) is suggested less often here than across Hackney: on 28% of certificates, against 47%.
Floor insulation is suggested less often here than across Hackney: on 1% of certificates, against 17%.
Ask an installer about insulation
Heat pump grants across Hackney
Boiler Upgrade Scheme figures are published for local authorities, not postcode districts. Across Hackney, 178 heat pump installations have had a grant paid (May 2022 to September 2026).
Installers in and around Hoxton East & Shoreditch (EC2A)
Companies House-registered installers listed for Hoxton East & Shoreditch: 100 installers have their registered office within 3 miles, 6 more say on their website that they work across Hackney and 24 more only name the county on their website. 33 of the 130 mention heat pumps.
The typical firm has been trading for 5 years (the median, from Companies House incorporation dates).
The first listed are Perkins Solutions Limited, Bright Nest Energy Ltd and Climate Innovations Ltd.
Perkins Solutions Limited
Says it fits air source heat pump, ground source heat pump, water source heat pump, solar PV, battery storage, EV charging, boilers
Says it holds MCS, TrustMark, RECC, NICEIC
Bright Nest Energy Ltd
Says it fits air source heat pump, solar PV, battery storage, EV charging, boilers, cavity wall insulation, loft insulation, solid wall insulation
Says it holds MCS, TrustMark, RECC, Gas Safe, PAS 2030, PAS 2035
Climate Innovations Ltd
Says it fits air source heat pump, boilers
Says it holds MCS
The Green Energy Group UK Ltd
Says it fits air source heat pump, battery storage, boilers, solar PV
Says it holds MCS, RECC, TrustMark
Says it fits air source heat pump, solar thermal, biomass, underfloor heating, boilers
Says it holds MCS, TrustMark, NAPIT, Gas Safe
Plumbology Ltd
Says it fits air source heat pump, solar PV, battery storage, underfloor heating, boilers
Says it holds MCS, Gas Safe
Heat Geek Installations Ltd
Says it fits air source heat pump, ground source heat pump, battery storage, boilers
Says it holds MCS, Which? Trusted Trader
Habitan Group Ltd
Says it fits air source heat pump, solar PV, underfloor heating, boilers
Says it holds MCS, RECC
Econegy Ltd
Says it fits air source heat pump
Says it holds MCS
LOW Carbon London Ltd
Says it fits air source heat pump, ground source heat pump, solar PV, solar thermal, EV charging, boilers
Says it holds MCS
CB Heating Ltd
Says it fits air source heat pump, ground source heat pump, water source heat pump, solar PV, battery storage, EV charging, underfloor heating, boilers
Says it holds MCS, Which? Trusted Trader
GB Second Shelf Company Limited
Says it fits air source heat pump
Greener Home Heating Limited
Says it fits air source heat pump, solar PV, solar thermal, battery storage, EV charging, biomass, underfloor heating
Pure Green Energy & Heating Ltd
Says it fits air source heat pump, ground source heat pump, solar PV, solar thermal, battery storage, boilers
Says it holds Gas Safe
SLM Property Solutions Ltd
Says it fits air source heat pump, underfloor heating, boilers
Capital Energy Group Ltd
Says it fits air source heat pump, solar PV, battery storage, EV charging, underfloor heating, boilers, cavity wall insulation, loft insulation, solid wall insulation
Carbon Energy Savings Ltd
Says it fits air source heat pump, solar PV, battery storage, EV charging
QDS Group Ltd
Says it fits air source heat pump, air to air heat pump, solar PV, battery storage, boilers
Eco Target Ltd
Says it fits air source heat pump, solar PV, battery storage
Masper Engineering Ltd
Says it fits air source heat pump, solar PV, EV charging, underfloor heating, boilers
Next Step Heating Limited
Says it fits air source heat pump, solar PV, solar thermal, boilers
Solar Armour Limited
Says it fits solar PV, battery storage, EV charging
Says it holds MCS, HIES, NAPIT
CAL Electrical Solutions Limited
Says it fits solar PV, battery storage, EV charging
Says it holds MCS, HIES, NAPIT
Baltic Electric Ltd
Says it fits solar PV, battery storage, EV charging
Says it holds MCS, NAPIT
These are the first 24 of 130: firms that name this area first, then those with a registered office nearby, then those that cover the wider area; heat pump firms and the nearest first within each.
Listed from each firm's own website and from Companies House records (contains public sector information licensed under the Open Government Licence v3.0). Being listed is not a recommendation, and what firms say about themselves has not been checked: ask for an installer's MCS certificate number and consumer code membership before you sign anything.
How Hoxton East & Shoreditch (EC2A) compares with Hackney
Privately rented homes are more common here than across Hackney: 66% of certificates, against 40%.
Socially rented homes are less common here than across Hackney: 6% of certificates, against 30%.
Homes with solid walls are less common here than across Hackney: 32% of certificates, against 50%.
Advice written for Hackney as a whole may not fit Hoxton East & Shoreditch on these points.
Hoxton East & Shoreditch (EC2A) and its neighbours
Bunhill (EC1Y) is about 1 mile away, over the border in Islington. Privately rented homes are less common there: 33% of certificates, against 66% in Hoxton East & Shoreditch.
Bishopsgate (EC2M) is about 1 mile away, over the border in City of London. Homes not on mains gas are more common there: 79% of certificates, against 25% in Hoxton East & Shoreditch.
City and County of the City of London (EC2Y) is about 1 mile away, over the border in City of London. Homes not on mains gas are more common there: 77% of certificates, against 25% in Hoxton East & Shoreditch.
How Hoxton East & Shoreditch (EC2A) ranks within Hackney
Of the 5 Hackney postcode districts with a page on this site, Hoxton East & Shoreditch (EC2A) has the lowest share of homes with solid walls (32%), the lowest share of homes with unfilled cavity walls (2%) and the highest share of homes not on mains gas (25%).
Grants and support (England)
The Boiler Upgrade Scheme rules (who qualifies, what it covers and how the installer applies) are summarised on the Hackney page, with a link to the official GOV.UK guidance.